20:10:39:44Data

Section · Administrative Rules of South Dakota · View on sdlegislature.gov ↗

Rulemaking activity

collection for the secondary neutral voltage drop test. The following data shall be collected for each secondary neutral tested: (1) Gauge and type of neutral wire; (2) Length of neutral wire; (3) Neutral current; (4) Voltage drop between both ends of the secondary neutral being tested; (5) Cow contact voltage or cow contact current at the same points used in the 48 hour test; (6) Voltage from the primary neutral at the transformer to remote reference electrode; and (7) Voltage from secondary neutral in the service panel serving the area of the cow contact point to the remote reference electrode.