61:15:06:06Floor

Section · Administrative Rules of South Dakota · View on sdlegislature.gov ↗

covering requirements. Interior floor finish materials in a group family day care home shall be a Class 2 material in required exits, exit passageways, or corridors providing exit access. A Class 2 material is any material having a minimum critical radiant flux of 0.22 watts per square centimeter as established by the procedures specified in NFPA-253, "Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source," 2015 edition. If an automatic sprinkler system is installed, floor covering materials need not be classified. Floor covering requirements apply to new construction and to replacing of floor covering in an existing facility.

Source: 18 SDR 107, effective January 1, 1992; 23 SDR 32, effective September 11, 1996; 33 SDR 113, effective January 2, 2007; 37 SDR 235, effective June 28, 2011; 43 SDR 56, effective October 17, 2016.