74:02:08:07Minimum spillway
Section · Administrative Rules of South Dakota · View on sdlegislature.gov ↗
design flood requirements -- Exception. The hydraulic capacity of a dam must, by category and size, be such that the following minimum spillway design floods can be passed through the spillways without overtopping the structure: CATEGORY SIZE SPILLWAY DESIGN FLOOD 3 Small 50-year frequency unless dam qualifies for § 74:02:08:07.01 exception Intermediate 100-year frequency Large 0.5 PMF 2 Small 100-year frequency Intermediate 0.5 PMF, unless dam qualifies for § 74:02:08:07.02 exception Large PMF 1 Small 0.5 PMF Intermediate 0.5 PMF Large PMF A spillway system for a dam must meet the requirements in this section unless the owner can provide information and justification to show the chief engineer that the proposed design flow can be stored, passed through, or passed over the dam without failure of the dam or if a variance is granted pursuant to SDCL 46-7-5.3.
Source: 13 SDR 49, effective October 27, 1986; 13 SDR 129, 13 SDR 141, effective July 1, 1987; 13 SDR 197, effective July 2, 1987; 14 SDR 67, effective November 8, 1987.