74:53:01:22Alternative method of
Section · Administrative Rules of South Dakota · View on sdlegislature.gov ↗
determining wastewater flow capacity requirements for public parks and marinas. In lieu of calculating the wastewater flow capacity required pursuant to § 74:53:01:20, Table 4 may be used to determine wastewater flow capacity for public parks and marinas when the usage cannot be accurately determined. Flow projections, expressed as gallons per fixture per hour, are based on the related statistical flow figures per unit of plumbing fixture. To determine the flow capacity of the system, multiply the number of hours the facility is open by the flow figure for each fixture available as given in Table 4. TABLE 4 Type of Fixture Gallons/Hour Faucets 15 Flush Toilets 35 Showers 100 Urinals 10
Source: 12 SDR 2, effective July 18, 1985; 13 SDR 129, 13 SDR 141, effective July 1, 1987; transferred from § 74:03:01:59, July 1, 1996.